For full functionality of this site it is necessary to enable JavaScript.

Ainuo AN9671X(F)Insulation Resistance tester (1~2000M)

+ Insulation Resistance Test
Output Voltage Setting and Measurement Range:  100V ~1000V DC 5V/step 
Test Time Setting Range: 1.0~999.9s 0.1s/step
Lower limit of Insulation Resistance: 1~2000M
Upper limit of Insulation Resistance: 1~2000M (0=off)
Insulation Resistance Range: 1~2000M, auto shift level 
Interface: RS232(RS485 optional), Remote control(PLC)
Dimension W×H×D(mm): 320×110×400

Details

 

Product Detail

Main features
* Latest international standard:Comply with CCC,IEC,EN,VDE,BS,UL,JIS standard requirements.
* Voltage ramp up/down,satisfy latest industrial standard requirements
* Breakdown current upper/lower limit setting,intelligent judgment,sound and light alarm
* AC 50/60HZ output
* Over voltage,over current protection,manual test wires compensation
* VFD display,simple operation
* Remote,RS232/485 interface

* Satisfy low voltage distribution industry latest requirements

Spec.

Model

AN9602X(F)

AN9605X(F)

AN9632X(F)

AN9671X(F)

AC Hipot Test

Rated Output

500VA
AC: 5kV/100mA

100VA(AC: 5kV/20mA)

 

Output Voltage Set and Range

0.2kV5.00kV AC,100mA 10V/step

0.2kV5.00kV AC, 10V/step

 

Output Voltage Adjustable Rate

±(2.5% of setting+10V)

 

Output Voltage Resolution/Accuracy

10V, ±(2.5% of setting+10V)

 

Output Frequency Range

50Hz, 60Hz (Optional)

 

Output Waveform

Sine waveform, pure resistance, above 200V, distortion <5%

 

Upper and Lower Limit Leakage Current Setting

AC: Upper: 0.10100.00mA, Lower:0.10100.00mA(0=disable), 0.01mA/step

AC: Upper: 0.1020.00mA, Lower:0.1020.00mA(0=disable), 0.01mA/step

 

Breakdown Current Measurement Range

0.1003.499mA/3.50100.00mA

0.1003.499mA/3.5020.00mA

 

Breakdown Current Accuracy

±(2.5% of reading+5 counts)

 

Ramp-up Time Setting Range/Resolution

1.0999.9s (0=disable) 0.1s/step

 

Test Time Setting Range/Resolution

1.0999.9s (LLL=continues) 0.1s/step

 

Test wire compensation

00.500mA, manual clear offset

 

Insulation Resistance Test

Output Voltage Setting and Measurement Range

 

100V 1000V DC 5V/step

Output Voltage Resolution/Accuracy

 

1V , ±(3% of setting+5V)

DC Ripple Coefficient

 

≤5% (1kV DC, <1mA, resistance load)

Output Voltage Adjustable Rate

 

±(3% of setting+5V)

Test Time Setting Range

 

1.0999.9s 0.1s/step (LLL= continues)

Lower limit of Insulation Resistance

 

12000M

Upper limit of Insulation Resistance

 

12000M (0=off)

Insulation Resistance Range

 

12000M, auto shift level

Insulation Resistance Accuracy

 

5001000V: ±(3% of reading+8counts) 1200M;
±(8% of reading+8counts) 200
2000M
Below 500V: ±(5% of reading+8counts) 1
200M;
±(10% of reading+8counts) 200
2000M

Interface Function

RS232(RS485 optional), Remote control(PLC)

Dimension W×H×D(mm)

450×150×440

320×110×400

               

 

 

  • Quality Engagement
  • Easy change and return
  • Delivery Avaliable
  • Favorable payment