For full functionality of this site it is necessary to enable JavaScript.

Ainuo ANFS045A(F) AC Power Supply (45kVA, 68.2A, 300.0V)

Input:  3-phase 4-wires,AC: 380V±57V,50/60Hz±3Hz 
Output Capacity: 45kVA    
Output Frequency: 45.0~240.00Hz
Frequency Stability: ≤0.02%
Output Mode: 3 phaes mode, Seperated 3 phaes mode,parallel mode
Output Current: 68.2A
Line Regulation: ≤1%     
Load Regulation: ≤1%
Phase retardation: 120°+2°
Modulating voltage range: ≤3V 
Protection Mode: IGBT hot, IGBT OverCurrent, Transformer hot, Input Lack Voltage, Input Over Voltage, Output Lack Voltage, Output Over Voltage, Output Over Current, Output Over Power, Lack Output Phase 
Voltage Drop Compensation: 0.000~0.500Ω 
Communication:RS232(Standard), RS485(Options), GPIB(Options),Ethernet(Options)
Remote Control:Analog Control(Options) 
Dimension  W×H×D(mm): 700*1330*1218
Weihgt (kg): 470

Details

 

Product Detail

Main features
* Adopt FPGA digital technology,realize precision control and high quality sine wave output;
* Advanced power output mode management:standard three-phase output,separated three-phase output(three-phase voltage and frequency adjusted independently), parallel single-phase output(three phase parallel,single-phase output)to achieve multi-function;
* Operating in over current shock(up to 3 times of rated current) within 2s,start the impact load of 1/3 capacity of powersupply directly;
* Adjustable voltage and frequency during output status,frequency change without transit time;
* Online monitoring:monitor IGBT temperature,transformer temperature,fan speed,input voltage and other parameters during output status;
* Operating data recorders:keep the record of power supply status and alarm code automatically during alarming,save the maintencance time;
* Fan speed will be adjustable automatically with the temperature of power supply to reduce the noise;
* Lock key,user-friendly design,automatically locking without operation for 5 minutes to prevent from opreation mistakes,
* 8 inch color LCD screen;
* Standard RS232,optional RS485,GPIB,Ethernet,analog control and other remote communication/control.

Order and Extensions
* ANFC three-phase AC pwer supply:1.0-300.0v/45.0-65.0HZ,100HZ,120HZ,200HZ,240HZ,optional 15kva,30kva,45kva,60kva,90kva,120kva,180kva,240kva.larger capacity can be modified.
* Communication interfaces:Standard RS-232, optional RS485,GPIB,Ethernet(Remarks:only can select one of RS-232,RS-485,GPIB,Ethernet).
* Remote control interface:optional analog control interface.
* PC control software

Spec.

Model/Specification

ANFS015A(F)

ANFS030A(F)

ANFS045A(F)

ANFS060A(F)

ANFS090A(F)

ANFS120A(F)

ANFS180A(F)

ANFS240A(F)

Input

3-phase 4-wiresAC 380V±57V50/60Hz±3Hz

Output Capacity

15kVA

30kVA

45kVA

60 kVA

90 kVA

120 kVA

180kVA

240KVA

Output Frequency

45.0~240.00Hz

Frequency Stability

≤0.02%

Output Mode

3 phaes mode, Seperated 3 phaes mode,parallel mode

Output Current

110V

45.4A

90.9A

136.3A

181.8A

272.7A

363.6A

545.4A

727.2A

220V

22.7A

45.4A

68.2A

90.9A

136.3A

181.8A

272.7A

363.6A

Accuracy

Voltage

Resolution0.1V

Accuracy0.2%×reading+0.2%×F.S. (45Hz—65Hz)

Current

Resolution0.1A/1A

Accuracy0.3%×reading+0.3%×rated output

Frequency

Resolution0.1Hz Accuracy0.05%

Power

Resolution 0.1kW / 0.01kW / 0.001kW

Accuracy 0.45%×reading+0.45%×F.S. (45Hz—65Hz)

Line Regulation

≤1%

Load Regulation

≤1%

Voltage Distortion

Linear load THD1.5%(110V±10%220V±10%45-65Hz)

Transient time

20ms

Phase retardation

120°+2°

Phase unbalance factor

1%

Crest factor

1.41±0.1

Modulating voltage range

3V

Over Power

105%≤Output110% the output will be stopped within 15 Sec.

110%≤Output210% the output will be stopped within 5 Sec.

200%≤Output300% the output will be stopped within 2 Sec.

300%≤Output the output will be stopped immediately

Protection Mode

IGBT hotIGBT OverCurrentTransformer hotInput Lack VoltageInput Over VoltageOutput Lack VoltageOutput Over VoltageOutput Over CurrentOutput Over PowerLack Output Phase

Voltage Drop Compensation

0.000~0.500Ω

Softstart Time

0.0~99.9S

Efficiency

86%

Shortcut Group

7 groups

Online Voltage Adjustment

The output voltage and frequency(45-65Hz) can be adjusted online under running status.

Communication/

Remote Control

CommunicationRS232Standard)RS485Options)GPIBOptions)EthernetOptions)</s