Fluke 9143 Field Metrology Wells (33 °C to 350 °C, ± 0.02 °C)
Manufacturer: Fluke (Calibration) Model: 9143 - Request a Quotation
- Contact
See more: Equipment Calibration-Inspection & Repair Service
Call for the best priceHanoi city: (024) 35.381.269
Danang city: (023) 63.747.711
Bac Ninh city: (0222)730.39.68
HCM city: (028) 38.119.636
Temperature Range at 23 °C: 33 °C to 350 °C (91 °F to 662 °F)
Display Accuracy: ± 0.02 °C at 33 °C
Stability:
± 0.02 °C at 33 °C
± 0.02 °C at 200 °C
± 0.03 °C at 350 °C
Axial Uniformity at 40 mm (1.6 in):
± 0.04 °C at 33 °C
± 0.1 °C at 200 °C
± 0.2 °C at 350 °C
Radial Uniformity:
± 0.01 °C at 33 °C
± 0.015 °C at 200 °C
± 0.02 °C at 350 °C
Hysteresis: 0.03
Immersion (Well) Depth: 150 mm (5.9 in)
Insert OD: 25.3 mm (1.00 in)
Heating Time: 5 min: 33 °C to 350 °C
Cooling Time: 32 min: 350 °C to 33 °C
Resolution: 0.01 °
Display: LCD, °C or °F user-selectable
Size (H x W x D): 290 mm x 185 mm x 295 mm
Weight: 7.3 kg
Power Requirements: 100 V to 115 V (± 10 %), 50/60 Hz, 1400 W 230 V (± 10 %), 50/60 Hz, 1800 W
Computer Interface: RS-232 and 9930 Interface-it control software included
Include:
Users Manual
echnical Manual on CD
Serial Cable
9930, Interface-it Software
Report of Calibration
Insert Removal Tool
Insert (option)
Base Unit Specifications | |||||||||||||||
Temperature Range at 23 °C |
|
||||||||||||||
Display Accuracy |
|
||||||||||||||
Stability |
|
||||||||||||||
Axial Uniformity at 40 mm (1.6 in) |
|
||||||||||||||
Radial Uniformity |
|
||||||||||||||
Loading Effect (with a 6.35 mm reference probe and three 6.35 mm probes) |
|
||||||||||||||
Hysteresis |
|
||||||||||||||
Operating Conditions |
|
||||||||||||||
Environmental Conditions (for all specifications except temperature range) |
|
||||||||||||||
Immersion (Well) Depth |
|
||||||||||||||
Insert OD |
|
||||||||||||||
Heating Time |
|
||||||||||||||
Cooling Time |
|
||||||||||||||
Resolution |
|
||||||||||||||
Display |
|
||||||||||||||
Size (H x W x D) |
|
||||||||||||||
Weight |
|
||||||||||||||
Power Requirements |
|
||||||||||||||
Computer Interface |
|
-P Specifications | |||||||||
Built-in Reference Thermometer Readout Accuracy (4-Wire Reference Probe)† |
|
||||||||
Reference Resistance Range |
|
||||||||
Reference Resistance Accuracy‡ |
|
||||||||
Reference Characterizations |
|
||||||||
Reference Measurement Capability |
|
||||||||
Reference Probe Connection |
|
||||||||
Built-in RTD Thermometer Readout Accuracy |
|
||||||||
RTD Resistance Range |
|
||||||||
RTD Resistance Accuracy‡ |
|
||||||||
RTD Characterizations |
|
||||||||
RTD Measurement Capability |
|
||||||||
RTD Connection |
|
||||||||
Built-in TC Thermometer Readout Accuracy |
|
||||||||
TC Millivolt Range |
|
||||||||
Voltage Accuracy |
|
||||||||
Internal Cold Junction Compensation Accuracy |
|
||||||||
TC Connection |
|
||||||||
Built-in mA Readout Accuracy |
|
||||||||
mA Range |
|
||||||||
mA Connection |
|
||||||||
Loop Power Function |
|
||||||||
Built-in Electronics Temperature Coefficient (0 °C to 13 °C, 33 °C to 50 °C) |
|
- Quality Engagement
- Easy change and return
- Delivery Avaliable
- Favorable payment