- Low pressure sensor
+ -14 psi to +16 psi, -0.97 bar to 1.1 bar
+ Accuracy: 0.025 % of full scale
- High pressure sensor
+ 0 psi to +1000 psi, 0.00 bar to 69 bar
+ Accuracy: 0.025 % of full scale
- mA measure:
+ Range: 0 to 24 mA
+ Resolution: 0.001 mA
+ Accuracy: ±0.015% of rdg ±0.002mA
- VDC measure:
+ Range: 0 to 30 VDC
+ Resolution: 0.001V
+ Accuracy: ±0.015% of rdg ±0.002V
- Temperature measure (RTD/ Ohms)
+ Range: -40 °C to 150 °C (-40 °F to 302 °F)
+ Resolution: 0.01 °C, 0.01 °F
+ Accuracy: ±0.015% of rdg, ±0.02 ohms
- Loop power supply: 24V
Batteries: (4) Standard AA cells
Dimensions: 20 cm X 11 cm X 5.8 cm
Include:
Dual Sensor Pressure Calibrator
Soft case
Four (4) AA batteries
Manual
Traceable calibration certificate
Test leads
Specifications 1-Year |
|||
Low pressure sensor |
Range |
Resolution |
Accuracy |
-14 psi to +16 psi, |
0.001 psi, |
0.025 % of full scale |
|
High pressure sensor |
0 psi to +1000 psi |
0.1 psi |
0.025 % of full scale |
General Specifications |
|||
Instrument setup recall |
Last used on power-up |
||
Environmental |
Operating temperature -10 °C to +50 °C |
||
Altitude |
2,000 meters |
||
Ingress protection |
IP-40 |
||
Power requirements |
6.0 v dc |
||
Battery life |
>35 hours, typical usage |
||
Batteries required |
(4) Standard AA cells |
||
Dimensions (HxWxD) |
7.9" X 4.3" X 2.3" (20 cm X 11 cm X 5.8 cm) |
||
Weight |
03539 kg (1 lb 3 oz) |
||
Connectors/ports pressure |
Two, 1/8 in NPT, 700P Series Pressure Module; RTD Probe |
||
Electrical and Temperature Measurement 1-Year |
|||
Function |
Range |
Resolution |
Accuracy |
mA measure |
0 to 24 mA |
0.001 mA |
±0.015% of rdg |
VDC measure |
0 to 30 VDC |
0.001V |
±0.015% of rdg |
*Temperature measure (RTD/ Ohms) |
-40 °C to 150 °C |
0.01 °C, 0.01 °F |
±0.015% of rdg |
Loop power supply |
24V |
N/A |
24 mA @ 24V |
*Temperature measurement requires optional Fluke-720RTD Pt-100 RTD probe available as an accessory |
|||
Temperature Effect |
|||
No effect on accuracy on all functions from 15 °C to 35 °C |
|||
Add ± 0.002 % F.S./°C for temps outside of 15 °C to 35 °C |
|||
Available Pressure Engineering Units |
|||
psi, bar, mbar, kPa, kgcm2, cmH2O@4°C, cmH2O@20°C, mH2O@4°C, mH2O@20°C, inH2O@4°C, inH2O@20°C, inH2O@60°F, mmHg@0°C, inHg@0°C, ftH2O@4°C, ftH2O@20°C, ftH2O@60°F |
Test Probes | |
Fluke 720RTD | RTD Probe for 721 and 719Pro |
Batteries, Chargers and Adapters | |
Fluke-720URTDA | Universal RTD Adapter for Fluke 721 and 719Pro |