Manufacture: Hanna
Model: HI84529-02
Warranty: 12 month

Range: Low Range: %l.a.: 0.01 to 0.20; °SH: 0.4 to 8.9; °D: 1.0 to 20.0; °Th: 1.1 to 22.2 High Range: %l.a.: 0.1 to 2.0; °SH: 4.4 to 88.9; °D: 10 to 200; °Th: 11.1 to 222.2
Resolution: Low Range: %I.a.: 0.01 ; °SH: 0.1; °D: 0.1; °Th: 0.1 High Range: %I.a.: 0.1; °SH: 0.1; °D: 1; °Th: 0.1
Accuracy (@25ºC/77ºF): Low Range: ± 0.01 %l.a. High Range: ± 0.1 %l.a.
Sample Volume: LR 20: 20 mL or 20 g LR 50: 50 mL or 50 g HR 20: 20 mL or 20 g
Methods: acid base titration
Principle: endpoint titration, adjustable (pH 8.0 - 8.7 in 0.1 increments)
Pump Speed: 10 mL/min
Stirring Speed: 800 (Low Range) / 1000 (High Range)
pH Range: -2.0 to 16.0 pH; -2.00 to 16.00 pH
pH Resolution: 0.1 pH / 0.01 pH
pH Accuracy (@25ºC/77ºF): ±0.01 pH
pH Calibration: one, two, or three-point calibration, four available buffers (4.01, 7.01, 8.20, 10.01)
Temperature Compensation: manual or automatic
mV Range: -2000.0 to 2000.0 mV
mV Resolution: 0.1 mV
mV Accuracy (@25ºC/77ºF): ±1.0 mV
Temperature Range: -20.0 to 120.0°C; -4.0 to 248.0°F; 253.2 to 393.2 K
Temperature Resolution: 0.1°C; 0.1°F; 0.1K
Temperature Accuracy (@25ºC/77ºF): ±0.4°C; ±0.8°F; ±0.4 K
Logging Data: up to 400 ( 200 titrations, 200 pH/mV readings)
Electrode: FC260B pH electrode with 1 m cable (included), HI5315 reference probe with 1 m cable (included)
Temperature Probe: HI7662-M stainless steel temperature probe with 1 m cable (included)
Environment: 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Power Supply: 12 VDC adapter (included)
Dimensions: 235 x 200 x 150 mm (9.2 x 7.9 x 5.9”)
Weight: 1.9 kg (67.0 oz.)
Ordering Information: HI84529-02 is supplied with FC260B pH electrode, HI5315 reference electrode, HI7662-M temperature probe, HI84529-50 low range 20 titrant (120 mL), HI84529-52 low range 50 titrant (120 mL), HI84529-51 high range 20 titrant (120 mL), HI84529-55 calibration standard (230 mL), HI7072 fill solution (30 mL), HI700640 cleaning solution for milk deposits (2 x 20 mL), capillary dropper pipette, 100 mL beakers (2), dosing pump valve, 5 mL syringe, 1 mL plastic pipette, tube set (aspiration tube with titrant bottle cap and dispensing tube with tip), stir bar, 12VDC power adapter, instruction manual and quality certificate.