KEITHLEY 2306-VS Dual-Channel Battery/Charger Simulator with External Triggering (15VDC, 5A)

Output #1 (Battery)
DC VOL TAGE OUTPUT (2 Years, 23°C ± 5°C)
OUTPUT VOLTAGE: 0 to +15VDC.
OUTPUT ACCURACY: ±(0.05% + 3mV).
PROGRAMMING RESOLUTION: 1mV.
READBACK ACCURACY1: ±(0.05% + 3mV).
READBACK RESOLUTION: 1mV.
LOAD REGULATION: ±(0.01% + 2mV).
LINE REGULATION: ±0.5mV.
STABILITY2: ±(0.01% + 0.5mV).
MEASUREMENT TIME CHOICES: 0.01 to 10 PLC7
, in 0.01PLC steps.
AVERAGE READINGS: 1 to 10.
READING TIME1, 8, 9: 31ms, typical.
TRANSIENT RESPONSE: High Bandwidth Low Bandwidth
Transient Recovery Time13 <40 s3="" br="">  or <60 s4="" 80="" s3="" br="">  or <100 s4="" br=""> Transient Voltage Drop <75 mv3="" br="">  or <100 mv4="" 250="" mv3="" br="">  or <400 mv4="" br=""> REMOTE SENSE: 1V max. drop in each lead. Add 2mV to the voltage load regulation specification
for each 1V change in the negative output lead due to load current change. Remote sense
required. Integrity of connection continually monitored. If compromised, output will turn off
automatically once settable window (±0 to ±8 volts) around normal voltage exceed
DC CURR ENT (2 Years, 23°C ± 5°C)
CONTINUOUS AVERAGE OUTPUT CURRENT:
Channel #2 (Charger) OFF: I = 50W/(Vset channel 1 + 6V); 5A max.
Channel #2 (Charger) ON: I = (50W – Power consumed by channel #2)/(Vset channel 1 + 6V);
5A max.
The power consumed by channel #2 is calculated as:
Channel #2 sourcing current: Power consumed = (Vset channel 2 + 6V) × (current supplied).
Channel #2 sinking current: Power consumed = 5 × (sink current).
Peak currents can be a maximum of 5A provided the average current is within the above limits.
CONTINUOUS AVERAGE SINK CURRENT:
Channel #2 (Charger) OFF:
0–5V: 3A max.
5–15V: Derate 0.2A per volt above 5V. Compliance setting controls sinking.
Channel #2 (Charger) ON:
Available current = (50W – Power consumed by channel #2)/5; 3A max. (0–5V).
Derate 0.2A per volt above 5V.
SOURCE COMPLIANCE ACCURACY: ±(0.16% + 5mA)5
.
PROGRAMMED SOURCE COMPLIANCE RESOLUTION: 1.25mA.
READBACK ACCURACY1: 5A Range: ±(0.2% + 200µA). 5mA Range: ±(0.2% + 1µA).
READBACK RESOLUTION: 5A Range: 100µA. 5mA Range: 0.1µA.
LOAD REGULATION: ±(0.01% + 1mA).
LINE REGULATION: ±0.5mA.
STABILITY4: ±(0.01% + 50µA).
MEASUREMENT TIME CHOICES: 0.01 to 10 PLC7
, in 0.01PLC steps.
AVERAGE READINGS: 1 to 10.
READING TIME1, 8, 9: 31ms, typical
Output #2 (Charger)
DC VOL TAGE OUTPUT (2 Years, 23°C ± 5°C)
OUTPUT VOLTAGE: 0 to +15VDC.
OUTPUT ACCURACY: ±(0.05% + 10mV).
PROGRAMMING RESOLUTION: 10mV.
READBACK ACCURACY1: ±(0.05% + 3mV).
READBACK RESOLUTION: 1mV.
OUTPUT VOLTAGE SETTLING TIME: 5ms to within stated accuracy.
LOAD REGULATION: ±(0.01% + 2mV).
LINE REGULATION: ±0.5mV.
STABILITY2: ±(0.01% + 0.5mV).
MEASUREMENT TIME CHOICES: 0.01 to 10 PLC7
, in 0.01PLC steps.
AVERAGE READINGS: 1 to 10.
READING TIME1, 8, 9: 31ms, typical.
TRANSIENT RESPONSE: High Bandwidth Low Bandwidth
Transient Recovery Time13 <50 s3="" br="">  or <80 s4="" 60="" s3="" br="">  or <100 s4="" br=""> Transient Voltage Drop <120 mv3="" br="">  or <150 mv4="" 160="" mv3="" br="">  or <200 mv4="" br=""> REMOTE SENSE: 1V max. drop in each lead. Add 2mV to the voltage load regulation specification
for each 1V change in the negative output lead due to load current change. Remote sense
required. Integrity of connection continually monitored. If compromised, output will turn off
automatically once settable window (±0 to ±8 volts) around normal voltage exceeded