Met One E-SAMPLER Aerosol Monitor
Manufacturer: METONE Model: E-SAMPLER - Request a Quotation
- Contact
See more: Equipment Calibration-Inspection & Repair Service
Call for the best priceHanoi city: (024) 35.381.269
Danang city: (023) 63.747.711
Bac Ninh city: (0222)730.39.68
HCM city: (028) 38.119.636
Manufacturer: Met One
Model: E-SAMPLER
Origin: USA
Warranty: 12 months
Features
- Programmable Auto-Zero
- Programmable Auto-Span
- Auto-ranging (1 to 65000 μm/m3)
- Automatic Flow Control Protocol
- Internal Battery (30 Hours Operation without heater & 10 Hours with heater.)
- Laser-Diode Precise Optical Engine
- Integral 47mm Analysis Filter
- Ambient Pressure and Temperature
- Internal Datalogger
- PM10, PM2.5, PM1, TSP Monitoring
- Aluminum Weatherproof Enclosure
- Purge-Air protected Optics
- Completely Self-Contained
- No Tools Filter Replacement
Specifications
Concentration Ranges (Auto-ranging): |
-0.5, 0-1, 0-10 0-65 mg/m3 |
Laser: | 670 nm, 5 mW |
Sensitivity: | 0.001mg/m3 |
Sample Period: | 1 sec |
Sample Flow Rate: | 2 LPM |
Pump Type: | Diaphram 10,000 hr |
Accuracy: | 8% of NIOSH 0600 |
Precision: | 0.003 mg/m3 or 2% reading |
Particle Size Sensitivity Range: | 0.1-100 micron |
Long term Stability: | 5% reading |
Sensor Type: | Forward Light Scatter |
Average Period: | 1 – 60 minutes |
Display: | 4X20 LCD |
Internal Battery (Optional): | 12 VDC 12 Amp-Hr, lead acid |
Power Consumption: | 350mA (no heater), 1.1 A (w/heater) |
Internal Battery Operation, no heater: | >30 Hours |
Internal Battery Operation, heater: | 10 Hours |
Size: | 10.5 (267) X 9.25 (235) X 5.7 (145) inches (mm) |
MOI Service Period: | 2 yrs |
Programmable Auto-Zero: | 15min to 24 hours |
Programmable Auto-Span: | 15min to 24 hours |
Traceable Testing: | Gravimetric |
Sample Line Heater: | Configurable RH Controlled |
Outputs: | Analog 0-1,0-2.5, 0-5VDC, RS232 |
Data Storage Capacity: | 12000 Records |
Temperature Compensation: | Standard |
Temperature Range: | -30C to +50C |
RH Measurement: | Internal |
Ambient Temperature: | -30C to +50C |
Ambient Pressure: | 1040 to 600 mbars |
Alarm: | Contact Closure |
Available Cut Points: |
TSP, PM10, PM2.5, PM1 |
Standard Equipment | ||
Universal Voltage Power Supply | ||
Battery Charger Internal | ||
47 mm Filter Holder | ||
Comet Software | ||
TSP Inlet | ||
Inlet Heater | ||
Digital Output Cable | ||
Instruction Manual |
Options | ||
PM10, PM2.5, PM1 Sharp-Cut Cyclone | ||
Low Temperature Option, -40C to +50C | ||
Aluminum Tripod | ||
MicroMet Software | ||
Radio Modem | ||
Satellite | ||
Wind Speed/Direction Sensor | ||
Ambient RH | ||
External Battery Cable | ||
Battery |
- Quality Engagement