Memmert HPP110 一定気候チャンバー(108L)

  • 生産者:MEMMERT
    Model: HPP110
    起源: Germany
    品物を保証します: 12 Month
    • 要件クオート Request a Quotation
  • 連絡先
    • カートへ追加
    • 今すぐ注文
  • 校正検証修理サービスを参照してください

      いい価格のため、連絡しなさい

    ホットライン: (+84) 968060220

    電話番号: +84 (24) 62923267

Volume: 108 liters

Interior dimension: width 560 x height 480 x depth 400 mm

Exterior dimension: width 745 x height 864 x depth 656 mm

Stainless steel grids: 2

Max. number of grids: 5

Working temperature range without humidity: 0 (at least 20 below ambient temperature) to 70°C

Working temperature range with humidity: +5 (at least 20 below ambient temperature) to 70°C

Setting temperature range without humidity: 0 – 70°C

Setting temperature range with humidity: 5 – 70°C

Setting accuracy: 0.1°C

2 Pt100 sensors DIN Class A in 4-wire-circuit for mutual monitoring, taking over functions in case of an error

Setting range humidity: 10 – 90% rh

Humidity supply with distilled water from external tank by self-priming pump

Humidification by hot steam generator

Dehumidification by cold trap using the Peltier technology

Setting accuracy: 0.5% rh

ControlCOCKPIT: TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays

Language settings: German, English, Spanish, French, Polish, Czech, Hungarian

Adjustable parameters: temperature (Celsius or Fahrenheit), relative humidity, programme time, time zones

Timer: Digital backwards counter with target time setting, adjustable from 1 minute to 99 days

Function SetpointWAIT: the process time does not start until the set temperature is reached.

Calibration: three freely selectable values each, temperature and humidity

Interface: Ethernet LAN, USB

Programme stored in case of power failure

Programming: AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port

ControlCOCKPIT with USB port for uploading programmes, reading out protocol logs, activating the User-ID function

Displaying of already logged protocol data on the ControlCOCKPIT (max 10000 values correspond to approx. 1 week)

Temperature control: over- and undertemperature monitor TWW, protection class 3.3 or adjustable temperature limiter TWB, protection class 2, selectable on display

Additionally integrated over and undertemperature protection "ASF", automatically following the setpoint value at a preset tolerance range, alarm in case of over or undertemperature, heating function is switched off in case of overtemperature, cooling function in case of undertemperature

Integral fault diagnostics for temperature and humidity control

Alarm: visual and acoustic

Energy-saving Peltier heating-/cooling system integrated in the rear

Structured stainless steel housing, scratch-resistant, robust and durable; rear of zinc-plated steel

Door: fully insulated stainless steel door with 2-point locking, inner glass door

Internal data logger with a storage capacity of least 10 years

Voltage: 230 V, 50/60 Hz

Electrical load: approx. 650 W.

Ambient temperature: 16 – 40°C

Humidity: max. 70% rh, non-condensing


Accessories:

+ Calibration certificate standard values 10°C and 37°C, 60% rh at 30°C (Memmert supply)

+ Stainless steel grids, 2 pcs

+ Water tank including connection hose