For full functionality of this site it is necessary to enable JavaScript.

Kasuga IOH-03 오버 헤드 이온화 장치

Ion generation method: DC corona discharge
Discharging electrode needle: Special alloy with low dust emission
Method of ion balance control : Control by D.I.C. circuit
Ion balance* Within ±10V (at time of factory shipment), permits fine tuning
Fan speed: Variable (non-step)
Maximum Air volume: 3.0 m3/min x 3 fan
Maximum airflow speed*: 0.87m/sec
-Alarm display: 
+ Alarm lamp blinking: Cleaning alarm (control limit), high-voltage alarm 
+ Alarm lamp staying lit: High-voltage stop (when voltage exceeds the control range or the high-voltage alarm continues)
- Alarm output (External output)
+ ionization output: During ionization (high-voltage output)
+ Alarm output: While alarm lamp blinks or stays lit
External input: Permits feedback input of electrostatic potential or ion balance
Amount of ozone production*: 0.02 ppm or less
Operating environment: Temperature: 0°C-40°C, Humidity: 80% RH or below (no condensation)
Input condition: AC100-240V (permits series connection of up to 10 units)
Power cable: Approx. 1.8 m (power cable with grounding electrode)
Power consumption: 54VA
Mass: Approx. 5.0kg

Details
  • Control by the new D.I.C. circuit* not only maintains a certain ion balance but also ensures a consistent amount of ion generation. This allows ionization in the optimal condition at all times, with no degradation of ionization performance. Frequency of maintenance can thus be significantly reduced.
  • The rear fan guard can easily be removed just by sliding it, which allows easy access to the area around the electrodes, ensuring easy maintenance.
  • When the ionizer is turned on, it displays the remaining interval before the next maintenance.
  • Electrode needles made of a special alloy with low dust emission allow use of the unit in a clean-room environment.

IOH-02-03_02.gif

When the unit is turned on, it displays the remaining interval before the next maintenance by the number of LED lamps lit.

*The D.I.C. (Double Ion Control) circuit maintains the optimal condition for static elimination by simultaneously controlling the ion balance and amount of ion generation.

Specifications

Model IOH-03  IOH-02
Ion generation method DC corona discharge
Discharging electrode needle Special alloy with low dust emission
Method of ion balance control Control by D.I.C. circuit
Ion balance* Within ±10V (at time of factory shipment), permits fine tuning
Fan speed Variable (non-step)
Maximum air volume 3.0 m3/min × 3 fans or 2 fans
Maximum airflow speed* 0.87m/sec 0.70m/sec
Alarm display Alarm lamp blinking Cleaning alarm (control limit), high-voltage alarm
Alarm lamp staying lit High-voltage stop (when voltage exceeds the control range or the high-voltage alarm continues)
Alarm output
(External output)
ionization output During ionization (high-voltage output)
Alarm output While alarm lamp blinks or stays lit
External input Permits feedback input of electrostatic potential or ion balance
Amount of ozone production* 0.02 ppm or less
Operating environment Temperature: 0°C-40°C, Humidity: 80% RH or below (no condensation)
Input condition AC100-240V (permits series connection of up to 10 units)
Power cable Approx. 1.8 m (power cable with grounding electrode)
Power consumption 54VA 32VA
Mass Approx. 5.0kg Approx. 3.6kg

*Measurement distance450mm

Ionization performance

IOH-02-03_03.gif

Dimensions [mm] and names of parts

IOH-03

IOH-02-03_04.gif

Intended use

  • Ionization in a wide area on the workbench used in cell production process
  • Ionization from objects on a conveyor 