Thiết bị đo lắp đặt điện đa chức năng Sonel MPI-502

  • Cam kết chất lượng
  • Bảo hành chính hãng
  • Giao hàng tận nơi
  • Đơn giản hóa giao dịch

Hãng sản xuất: Sonel

Model: MPI-502

Xuất xứ: Ba Lan

The device meets the requirements of EMC standards EN 61326-1:2006 and EN 61326-2-2:2006.
Electric safety:
- type of insulation: double, according to EN 61010-1 and IEC 61557
- measurement category: IV 300V (III 600V) according to EN 61010-1
- protection class acc. to EN 60529: IP67

Chi tiết

Other technical data:
- Dimentions: 220 x 98 x 58mm
- weight: ~1kg
- Auto OFF time: 300, 600, 900 second
- number of measurements Z and RCD (for NiMH batteries): >5000 (2 per minute)

Short circuit loop impedance measurement ZL-PE, ZL-N, ZL-L
Measurment using 7,6/13,3A current – Measurement range according to 
IEC 61557: 0,13...1999Ω

(for 1,2m lead) and 0,19...1999Ω (for WS-01 and WS-04). 

Display range Resolution Accuracy
0,00...19,99Ω 0,01Ω ±(5% m.v. + 3 dgt)
20,0...199,9Ω 0,1Ω
200...1999Ω

• Nominal work voltage: UnL-N/ UnL-L: 220/380V, 230/400V, 240/415V, 
• Voltage operating range: 100…264V (for ZL-PE i ZL-N) and 100…440V (for ZL-L), 
• Nominal network frequency fn: 50Hz, 60Hz, 
• Max. test current: 23A (230V), 44A (440V), 
• PE terminal connection corectores check with the help of touch electrode

Readings of fault loop impedance R and fault loop reactance XL 

Display range Resolution Accuracy
0,00...19,99Ω 0,01Ω ±(5% m.v. + 5 digits) of ZS value
20,0...199,9Ω 0,1Ω

calculated and displayed for ZS<200Ω.

Short circuit loop impedance ZL-PE in mode RCD – without RCD tripping 
Measurement using <15mA,current measurement range in accordance with IEC 61557: 0,51...1999,9Ω

Display range Resolution Accuracy
0,00...19,99Ω 0,01Ω ±(6% m.v. + 10 dgt)
20,0...199,9Ω 0,1Ω ±(6% m.v. + 5 dgt)
200...1999Ω

• test without tripping the RCD for IΔn ≥ 30mA,
• nominal work voltage: Un: 220V, 230V, 240V,
• voltage operating range:180...270V,
• frequency operating range fn: 50Hz, 60Hz 
• PE terminal connection correctness check with the help of touch electrode

Readings of fault loop impedance R and fault loop reactance XL (without tripping the RCD)

Display range Resolution Accuracy
0,00...19,99Ω 0,01Ω ±(6% m.v + 10 dgt) of ZS value 
20,0...199,9Ω 0,1Ω ±(6% m.v + 5 dgt) of ZS value

• calculated and displayed for ZS<200Ω.

RCD parameters test (voltage range 180...270V):
RCD tripping test and measurment of tripping time tA (for tA function)

Breaker Type Test Current
Multiplier
Range Resolution Accuracy
Standard 0,5*IΔn 0...300ms

1 ms



± (2% m.v. + 2 dgt)

 

1*IΔn
2*IΔn 0...150ms
5*IΔn 0...40ms
Selective 0,5*IΔn 0...500ms
1*IΔn
2*IΔn 0...200ms
5*IΔn 0...150ms

• Precision of the differential current: 0,5*IΔn:-8...0% for 1*IΔn, 2*IΔn, 5*IΔn: 0...8%

Voltage measurement

Range Range Accuracy
0,0V...299,99V 0,1V ±(2% m.v. + 6 dgt)
300V...500V 1V ±(2% m.v + 2 dgt)


Frequency measurement

Range Range Accuracy
45,0V...65,0Hz 0,1Hz ±(1% m.v. + 1 dgt)

 

Touch voltage measurement referred to the rated residual current (UB)

Range Resolution Test
Current 
Accuracy
0..9,9V 0,1V 0,4 x IΔn 10% m.v. ± 5 dgt 
10,0..99,9V 0...15% m.v.

Measurementof the RCD disconection current IA for sine waveform testing current

Selected
Current
Range Resolution Test
Current
Accuracy
10mA 3,3...10,0mA 0,1mA 0,3 x IΔn...1,0 x IΔn ±5%IΔn
30mA 9,0...30,0mA
100mA 33...100mA 1mA
300mA 90...300mA
500mA 150...500mA

• It is posible to start the measurement from the positive or negative half of the forced leaking current

RCD IA tripping current measurement for unidirectional pulsating residual current

Selected
Current
Range Resolution Test
Current 
Accuracy
10mA 4...20,0mA 0,1mA 0,35xIΔn..2,0xIΔn ±10%IΔn
30mA 12,0...42,0mA 0,35xIΔn..1,4xIΔn
100mA 40,0...140mA 1mA
300mA 120...420mA

• Measurement is possible for a positive or negative forced leakage current.

Low voltage test of the circuit and insulation continuity
Measurement range in accordance with IEC61557:0,12...400Ω
Test of PE wire continuity using a ±200mA current

Range Resolution Accuracy
0,00...19,99Ω 0,01Ω ±(2% m.v + 3 dgt)
20,0...199,9Ω 0,1Ω
200...400Ω

• Voltage on open terminals: 4…9V,
• Test current at R<2Ω: min. 200mA,
• Autocalibration of test leads
• Measurements for both polarizations of the current

„m.v.” measured value.