emin

Cs-instruments VA 550流量传感器适用于重型工业应用

  • 制造商: Cs-instruments
    Model: VA 550
    来源: Germany
    • 报价要求 报价要求
  • 60,696,026 VND
  • 价格合理详情请致电

    热线:   (+84) 966520220

    电话:  +84 (24) 62923267


      

  • 质量承诺
  • 正品保修
  • 送货到家
  • 交易简单化

Manufacturer: Cs-instruments

Model: VA 550
Made in: Germany

Measurement: volume, flow, consumption
               flow rate, temperature
Measurement principle: Heat flow sensor
Average temperature: -40 ... 180 ° C Probe (ATEX version -20 ° C ... 120 ° C)
Operating Temperature: -20 ... 70 ° C
Operating pressure: 50 bar
Power supply: 18 ... 36 VDC
Power consumption: up to 5W
Output: Modbus RTU (EIA / TIA-485 compliant)
             2 x 4 ... 20 mA
             Modbus TCP, HART, ProfibusDP, Profi Net,
Accuracy: ± 1,5% m.v. ± 0.3% f.s. (Standard version)
Accuracy: ± 1.0% m.V. ± 0.3% f.s. (Correct version) 
Response time: t90 <3 seconds
Display: 2 "TFT color display (320 x 240)
Fiberglass: G 1/2 "ISO 228, NPT 1/2", R 1/2 ", PT 1/2"
Protection class IP67

Option

Measuring range:

Bestell-Code

A1 - Standard version (92,7 m/s)

A1

0,00 €

A2 - Max version (185 m/s)

A2

435,00 €

A3 - High-Speed version (224 m/s)

A3

639,00 €

 

 

 

Screw-in thread:

 

 

B1 - G 1/2" outer thread

B1

0,00 €

B2 - NPT 1/2" outer thread

B2

81,00 €

B3 - PT 1/2" outer thread

B3

81,00 €

 

 

 

Mounting length / shaft length:

 

 

C1 - 220 mm

C1

0,00 €

C2 - 300 mm

C2

158,00 €

C3 - 400 mm

C3

259,00 €

C4 - 500 mm

C4

360,00 €

C5 - 600 mm

C5

416,00 €

C7 - 160 mm

C7

0,00 €

 

 

 

Option display:

 

 

D1 - with integrated display

D1

323,00 €

D2 - without display

D2

0,00 €

 

 

 

Option signal outputs / bus connection:

 

 

E1 - 2x4...20mA a. output,galv.isolated,pulse output RS485 Modbus-RTU

E1

116,00 €

E4 - 1x4…20mA analogue output (not galv. isolated), pulse output, RS 485 (Modbus RTU)

E4

0,00 €

E5 - Ethernet-Interface (Modbus/TCP), 1 x 4…20 mA analogue output (not galvanically isolated), pulse output, RS 485 (Modbus-RTU)

E5

220,00 €

E7 - 2x4..20mA analogue output passive,pulse output RS485 (Mb-RTU)

E7

116,00 €

E8 - M-Bus (Z6955504)

E8

173,00 €

E9 - Ethernet-Interface PoE (Power over Ethernet) (Modbus/TCP), 1 x 4…20 mA analogue output (not galvanically isolated), pulse output, RS 485 (Modbus-RTU)

 

E9

 

287,00 €

 

 

 

Calibration:

 

 

F1 - no real gas calibration - gas adjustment via gas constant

F1

0,00 €

F2 - real gas calibration in the gas type as selected below

F2

231,00 €

 

 

 

Gas type:

 

 

G1 - Compressed air

G1

0,00 €

G2 - Nitrogen (N2)

G2

0,00 €

G3 - Argon (Ar)

G3

100,00 €

G4 - Carbon dioxide (CO2)

G4

100,00 €

G5 - Oxygen (O2)

G5

100,00 €

G6 - Nitrous Oxide (N2O)

G6

100,00 €

G7 - Natural gas (NG)

G7

100,00 €

G8 - Helium (He)

G8

100,00 €

G9 - Propane (C3H8)

G9

100,00 €

G10 - Methane (CH4)

G10

100,00 €

G11 - Biogas (Methane 50% : CO2 50%)

G11

100,00 €

G12 - Hydrogen (H2)

G12

100,00 €

G90 -Further gas

G90

169,00 €

G91 - Gas mixture

G91

169,00 €

 

 

 

Maximum pressure:

 

 

H3 - 16 bar

H3

0,00 €

H1 - 50 bar (not for DVGW approval)

H1

0,00 €

H2 - 100 bar (not for DVGW approval)

H2

124,00 €

 

 

 

Surface condition:

 

 

I1 - Standard version

I1

0,00 €

I2 - Special cleaning - oil and grease free (e.g. for oxygen)

I2

163,00 €

I3 - LABS free and silicone free, special cleaning oil and grease free

I3

242,00 €

 

 

 

Accuracy class:

 

 

J1 - ± 1,5% of measured value (standard)

J1

0,00 €

J2 - ± 1 % of measured value (precision)

J2

203,00 €

 

 

 

Maximum gas temperature at the sensor tip:

 

 

K1 - up to 120°C gas temperature (only for ATEX - version)

K1

0,00 €

K2 - up to 180°C gas temperature (not for ATEX - version)

K2

0,00 €

 

 

 

Approvals:

 

 

L1 - Non-explosive area - no approval

L1

0,00 €

L2 - ATEX II 2G Ex d IIC T4

L2

693,00 €

L3 - DVGW approval (for natural gas)

L3

208,00 €

 

 

 

Reference conditions:

 

 

M1 - 20°C, 1000 hPa

M1

0,00 €

M2 - 0°C, 1013,25 hPa

M2

0,00 €

M3 - 15°C, 981 hPa

M3

0,00 €

M4 - 15°C, 1013,25 hPa

M4

0,00 €

 

 

 

R1 - Special measuring range

R1

107,00 €

Further accessories:

 

 

Connection cable for sensors 5 m with open ends

0553 0108

29,00 €

Connection cable for sensors 10 m with open ends

0553 0109

48,00 €

Ethernet connection cable length 5 m, M12 plug x-coded (8 poles) to RJ 45 plug

0553 2503

131,00 €

Ethernet connection cable length 10 m, M12 plug x-coded (8 poles) to RJ 45 plug

0553 2504

164,00 €

5 point precision calibration of new instrument with ISO certificate

3200 0001

405,00 €

Additional calibration point volume flow VA5xx serial, freely selectable

0700 7720

82,00 €

CS Service software incl. PC connection set for FA/VA 5xx sensors

0554 2007

295,00 €

High-pressure protection f. installation from 10 to 100 bar (for VA 550)

0530 1115

329,00 €

High-pressure protection f. installation from 10 to 16 bar DVGW (for VA 550)

0530 1116

329,00 €

PNG cable screwing - standard

0553 0552

8,00 €

PNG cable screwing – for ATEX

0553 0551

34,00 €

详细

datasheet

manual

Instruction Manual VA 5xx - Modbus RTU Slave Installation


注册收新闻 - 获得优惠活动的机会