Manufacturer: Testo
Model: Testo 350
Made in Germany
Warranty : 12 months

Technical Data

Temperature - NTC

Measuring range

-4° to 122 °F / -20 to +50 °C

Accuracy

±0.4 °F (14° to 122 °F) / ±0.2 °C (-10 to +50 °C)

Resolution

0.1 °F (-4° to 122 °F) / 0.1 °C (-20 to +50 °C)

Ambient temperature probe

Temperature - Type K TC

Measuring range

-328.0° to 2498.0 °F / -200 to +1370 °C

Accuracy

±0.7 °F (-148.0° to 392.0 °F) / ±0.4 °C (-100 to +200 °C)

±1.8 °F (-328.0° to -148.2 °F) / ±1 °C (-200 to -100.1 °C)

±1.8 °F (392.2° to 2498.0 °F) / ±1 °C (200.1 to +1370 °C)

Resolution

±0.1 °F (-328.0° to 2498.0 °F) / 0.1 °C (-200 to +1370 °C)

Temperature - TC Type S (Pt10Rh-Pt)

Measuring range

32.0° to 3200.0 °F / 0 to +1760 °C

Accuracy

±1.8 °F (32.0° to 3200.0 °F) / ±1 °C (0 to +1760 °C)

Resolution

±0.1 °F (32.0° to 3200.0 °F) / 0.1 °C (0 to +1760 °C)

Differential Pressure

Measuring range

-16 to +16 InH₂O / -40 to +40 hPa

-80 to +80 InH₂O / -200 to +200 hPa

Accuracy

±1.5 % of mv (-16 to -1 InH₂O) / ±1.5 % of mv (-40 to -3 hPa)

±1.5 % of mv (+1 to +16 InH₂O) / ±1.5 % of mv (+3 to +40 hPa)

±0.01 InH₂O (-1.20 to +1.20 InH₂O) / ±0.03 hPa (-2.99 to +2.99 hPa)

±1.5 % of mv (-80 to -20 InH₂O) / ±1.5 % of mv (-200 to -50 hPa)

±1.5 % of mv (+20 to +80 InH₂O) / ±1.5 % of mv (+50 to +200 hPa)

±0.2 InH₂O (-20.0 to +20.0 InH₂O) / ±0.5 hPa (-49.9 to +49.9 hPa)

Resolution

0.01 InH₂O (-16 to +16 InH₂O) / 0.01 hPa (-40 to +40 hPa)

0.1 InH₂O (-80 to +80 InH₂O) / 0.1 hPa (-200 to +200 hPa)

Absolute Pressure

Measuring range

240 to +460 InH₂O / 600 to +1150 hPa

Accuracy

±4 InH₂O / ±10 hPa

Resolution

1 InH₂O / 1 hPa

opt. when equipped with IR sensor

Flue gas O₂

Measuring range

0 to +25 Vol.%

Accuracy

±0.8% of fsv (0 to +25 Vol.%)

Resolution

0.01 Vol.% (0 to +25 Vol.%)

Reaction time t₉₀

20 sec (t95)

Flue gas CO

Measuring range

0 to +10000 ppm

Accuracy

±5 % of mv (+200 to +2000 ppm)

±10 % of mv (+2001 to +10000 ppm)

±10 ppm (0 to +199 ppm)

Resolution

1 ppm (0 to +10000 ppm)

Reaction time t₉₀

40 sec

H₂ only as an indicator

Flue gas COlow

Measuring range

0 to 500 ppm

Accuracy

±5 % of mv (+40 to +500 ppm)

±2 ppm (0 to +39.9 ppm)

Resolution

0.1 ppm (0 to +500 ppm)

Reaction time t₉₀

40 sec

H₂ only as an indicator

Flue Gas NO

Measuring range

0 to +4000 ppm

Accuracy

±5 % of mv (+100 to +1999 ppm)

±10 % of mv (+2000 to +4000 ppm)

±5 ppm (0 to +99 ppm)

Resolution

1 ppm (0 to +4000 ppm)

Reaction time t₉₀

30 sec

Flue gas NOlow

Measuring range

0 to +300 ppm

Accuracy

±5 % of mv (+40 to +300 ppm)

±2 ppm (0 to +39.9 ppm)

Resolution

±0.1 ppm (0 to +300 ppm)

Reaction time t₉₀

30 sec

Flue Gas NO₂

Measuring range

0 to +500 ppm

Accuracy

±5 % of mv (+100 to +500 ppm)

±5 ppm (0 to +9.99 ppm)

Resolution

0.1 ppm (0 to +500 ppm)

Reaction time t₉₀

40 sec

Flue Gas SO₂

Measuring range

0 to +5000 ppm

Accuracy

±5 % of mv (+100 to +2000 ppm)

±10 % of mv (+2001 to +5000 ppm)

±5 ppm (0 to +99 ppm)

Resolution

1 ppm (0 to +5000 ppm)

Reaction time t₉₀

30 sec

Efficiency (calculated)

Measuring range

0 to +120 %

Resolution

0.1 % (0 to +120 %)

Flue Gas loss (calculated)

Measuring range

0 to +99.9 %

Resolution

0.1 % (0 to +99.9 %)

Flue Gas dewpoint (calculated)

Measuring range

0 to +99.9 °Ctd

Resolution

0.1 °Ctd (0 to +99.9 °Ctd)

Flue Gas CO₂ calculation (calculated from O₂)

Measuring range

0 to CO₂ max

Accuracy

calculated from O₂ ±0.2 Vol.%

Resolution

0.01 Vol.%

Flue gas H₂S

Measuring range

0 to +300 ppm

Accuracy

±5 % of mv (+40 to +300 ppm)

±2 ppm (0 to +39.9 ppm)

Resolution

0.1 ppm (0 to +300 ppm)

Reaction time t₉₀

35 sec

Flue Gas CO₂ - NDIR

Measuring range

0 to +50 Vol.%

Accuracy

±0.3 Vol.% + 1 % of mv (0 to 25 Vol.%)

±0.5 Vol.% + 1.5 % of mv (25 to 50 Vol.%)

Resolution

0.01 Vol.% (0 to 25 Vol.%)

0.1 Vol.% (> 25 Vol.%)

Reaction time t₉₀

10 sec

Velocity / Volume flow

Measuring range

0 to +7874 fpm / 0 to +40 m/s

Resolution

19.7 fpm (0 to +7874 fpm) / 0.1 m/s (0 to +40 m/s)

Methane (CH₄)

Measuring range

100 to 40000 ppm

Accuracy

< 400 ppm (100 to 4000 ppm)

< 10 % of mv (> 4000 ppm)

Resolution

10 ppm

Min. O₂ requirement in flue gas

2 % + (2 x mv methane)

Reaction time t₉₀

< 40 sec

Response factor

1

Lower explosion limit (LEL) must be adhered to. 
The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user.

Propane (C₃H₈)

Measuring range

100 to 21000 ppm

Accuracy

< 400 ppm (100 to 4000 ppm)

< 10 % of mv (> 4000 ppm)

Resolution

10 ppm

Min. O₂ requirement in flue gas

2 % + (5 x mv propane)

Reaction time t₉₀

< 40 sec

Response factor

1.5

Lower explosion limit (LEL) must be adhered to. 
The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user.

Butane (C₄H₁₀)

Measuring range

100 to 18000 ppm

Accuracy

< 400 ppm (100 to 4000 ppm)

< 10 % of mv (> 4000 ppm)

Resolution

10 ppm

Min. O₂ requirement in flue gas

2 % + (6.5 x mv butane)

Reaction time t₉₀

< 40 sec

Response factor

2

Lower explosion limit (LEL) must be adhered to. 
The HC sensor is adjusted to methane ex-works. It can be adjusted to a different gas (propane or butane) by the user.

General technical data

Dimensions

13 x 5 x 17 in. / 330 x 128 x 438 mm

Operating temperature

23.0° to 113.0 °F / -5 to +45 °C

Housing

ABS

Protection class

IP40

Battery type

lithium batteries

Battery life

5 h

Power supply

AC mains unit 100V to 240V (50 to 60 Hz)

DC electric tension input

11V to 40V

Trigger input

Voltage 5 to 12 Volt (rising or trailing edge) pulse width > 1 sec load: 5 V/max, 5 mA, 12 V/max. 40 mA

Max. humidity load

70 °C dewpoint temperature

Dewpoint calculation

0 °Ctd; 99 °Ctd

Max. dust load

20 g/m³ dust in flue gas

Max. neg. press./flue gas

-4.4 psi / -300 mbar

Max. pos. press./flue gas

0.7 psi / 50 mbar

Hose length

16.2 m (corresponds to 5 probe hose extensions)

Pump flow

1 l/min. with through-flow monitoring

Maximum

250,000 readings

Storage temperature

-4.0° to 122.0 °F / -20 to +50 °C

Weight

169 oz. / 4800 g

详细

Datasheet

Manual

The testo 350 Portable Emission Analyzer

Whether you are testing for compliance or troubleshooting and tuning the testo 350 portable emission analyzer offers everything you need!

Control Unit - Provides remote control operation up to 300 ft away

  • Color graphic display is easy to see in dark or bright conditions
  • Go wireless with long-range 300 ft. Bluetooth (or wired to over 3,000 ft.) to eliminate long sample lines

Analyzer box - for high accuracy measurements

  • Contains up to six sensors, pumps, gas path, sample conditioning, and more
  • Conditions the gas sample automatically, thermoelectric (peltier) chiller as required by regulatory agencies

Test up to six gases simultaneously, or swap sensors out for additional parameters with field replaceable pre-calibrated digital sensors

  • Dilution system for the widest testing ranges and greatest sensor protection
  • Sample conditioning utilizes a thermoelectric chiller and a peristaltic hose pump for controlled water removal and EPA compliance
  • Automatic flow-controlled high strength pump
  • Proven sample gas path with Teflon® lined hoses
  • Continuous temperature compensation for assured accuracy
  • Flow rate and sensor temperature monitoring for US EPA CTM-030, -034, ASTM D6522, and SCAQMD 1110.2 and 1146 requirements
  • User defined programs with onboard memory to 250,000 values
  • User configured testing programs
  • Emission Rates: Real time display w/ EPA Method 19 Calculations
  • Mass flow and emission rates with pitot tube
  • User defined O2 reference for EPA and state reporting